Model: YC4108
Part Number: D0305-1307010A
Brands: Yuchai
Engine Model: YC4108
Engine Type: Diesel
Scope of application: light and medium trucks, agricultural machinery, generator sets, marine auxiliary
Yuchai used more than one coolant pump on the YC4108 depending on production period and accessory layout. Part D0305-1307010A is the alternative to D0305-1307020B, and the right one depends on the pulley and inlet arrangement fitted to the engine.
That detail matters more than it sounds. A pump with the correct casting but the wrong pulley offset will not align with the belt, and it destroys its own bearing within hours of running.
The pump fits YC4108 engines in trucks, agricultural machinery and gensets. Confirm the engine plate, the old pump number and the pulley diameter before ordering.
Compare the old pump with the new one: pulley diameter, inlet position and mounting face are the identifying features. Send a photo of the old pump beside a ruler and we will confirm which variant the engine needs.
Most premature failures trace back to belt alignment. A worn tensioner or the wrong pulley offset side-loads the bearing and the seal weeps within a few thousand hours. Check the belt path with a straight edge before fitting the new pump.
Field work packs the radiator core with chaff and dust. Clean the core with compressed air at every major service; this prevents more overheating than any component replacement and costs nothing.
Use the correct coolant mixture rather than plain water. Plain water scales the housing and radiator, reducing flow and shortening seal life.
Pumps are compact and do not deteriorate in storage. One spare pump with a gasket and a belt can turn a breakdown into a same-day repair.
Trapped air is the most common reason an engine overheats immediately after a pump replacement. Fill slowly at the highest point, open the heater circuit if fitted, and run the engine with the cap off until the thermostat opens. Then top up, fit the cap and recheck after the first cool-down.
A system that needs repeated topping up has a leak. On a diesel the leak is often the early stage of a head gasket failure, so investigate rather than simply refilling.
Inspect the belt for glazing and cracks, and check the tensioner for a rough bearing. A worn tensioner side-loads the new pump and undoes the repair. Re-tension the belt after the first heat cycle, because a new belt stretches slightly.
Mixing coolant brands or topping up with water repeatedly reduces inhibitor protection and allows scale to form in the pump housing and radiator. Drain and refill with a single correctly mixed coolant rather than topping up indefinitely. On a machine that works in the field, a clean system is cheaper than any component replacement.
Dispose of used coolant responsibly. It is toxic to animals and persists in soil, which matters on farms where the engine is serviced outdoors.
While the pump is off, inspect the thermostat housing for corrosion and the hoses for internal delamination. A hose that has broken down inside restricts flow and looks healthy from outside. Replace any hose that is soft, swollen or more than a few years old.
Use the correct clamps rather than wire types. A clamp that does not distribute load evenly cuts into the hose and produces a leak that appears only when the system is hot and pressurised.
Coolant pumps rarely fail suddenly; they fade. By the time the engine is overheating on a warm day, the bearing and seal have usually been deteriorating for months. Replacing the pump at the first sign of weep or noise is far cheaper than dealing with a warped head afterwards.
Compare the pulley and inlet arrangement, or send us a photo of the old pump.
Yes, the gasket is supplied.
Only to reach a workshop.
The pump comes with the hub.
Browse the Yuchai pump category, and pair the pump with the YC4108 water pump D0305-1307020B or the YC4108 oil pump D30-1011100.
Yuchai YC4108 Water Pump (1307010). The coolant pump circulates flow through the block and head. Its impeller, seal and bearing are matched to the housing, and the pulley mounting sets belt alignment.
Confirm the inlet angle and hose spigot position against the old pump. Two pumps can share a housing and differ in the direction the hose leaves.
Numbers beginning 1307 are used on WP6 and WP7 engines. The suffix, not the leading digits, distinguishes the variants. On this engine, confirm the YC4108 application against the engine plate before ordering.
Drain and refill with the correct coolant mix and bleed the system completely. Air in the system causes hot spots and accelerates cavitation damage on the liners.
Ordering note. Warranty is twelve months against manufacturing defects. Failures caused by incorrect clearance, overheating or debris are assessed on the returned part rather than refused outright.
Related reading: Cylinder Liner Cavitation: Causes, Symptoms and Prevention
| We Are 30 Years Diesel Engine Parts Supplier | |
| Brand | EPID |
| Warranty | 12 Months |
| Condition | 100%New |
| More Models | Weichai: YC4108, and other Weichai series. |
| Shipping | By sea / air / express (DHL, FEDEX, TNT, UPS, EMS) |
| Packing | Standard exporting packing or as required |
| Payment Term | L/C, T/T, Western Union, Trade Assurance |
| Delivery Time | 3-7 days (depend on order) |
| Selling Point | 1. On-time Delivery 2. Genuine Quality Assurance 3. Professional Supplier |
Compare the old pump with the new one: pulley diameter, inlet position and mounting face are the identifying features. Send a photo of the old pump beside a ruler and we will confirm which variant the engine needs.
Most premature failures trace back to belt alignment. A worn tensioner or the wrong pulley offset side-loads the bearing and the seal weeps within a few thousand hours. Check the belt path with a straight edge before fitting the new pump.
Field work packs the radiator core with chaff and dust. Clean the core with compressed air at every major service; this prevents more overheating than any component replacement and costs nothing.
Use the correct coolant mixture rather than plain water. Plain water scales the housing and radiator, reducing flow and shortening seal life.
Pumps are compact and do not deteriorate in storage. One spare pump with a gasket and a belt can turn a breakdown into a same-day repair.
Trapped air is the most common reason an engine overheats immediately after a pump replacement. Fill slowly at the highest point, open the heater circuit if fitted, and run the engine with the cap off until the thermostat opens. Then top up, fit the cap and recheck after the first cool-down.
A system that needs repeated topping up has a leak. On a diesel the leak is often the early stage of a head gasket failure, so investigate rather than simply refilling.
Inspect the belt for glazing and cracks, and check the tensioner for a rough bearing. A worn tensioner side-loads the new pump and undoes the repair. Re-tension the belt after the first heat cycle, because a new belt stretches slightly.
Mixing coolant brands or topping up with water repeatedly reduces inhibitor protection and allows scale to form in the pump housing and radiator. Drain and refill with a single correctly mixed coolant rather than topping up indefinitely. On a machine that works in the field, a clean system is cheaper than any component replacement.
Dispose of used coolant responsibly. It is toxic to animals and persists in soil, which matters on farms where the engine is serviced outdoors.
While the pump is off, inspect the thermostat housing for corrosion and the hoses for internal delamination. A hose that has broken down inside restricts flow and looks healthy from outside. Replace any hose that is soft, swollen or more than a few years old.
Use the correct clamps rather than wire types. A clamp that does not distribute load evenly cuts into the hose and produces a leak that appears only when the system is hot and pressurised.
Coolant pumps rarely fail suddenly; they fade. By the time the engine is overheating on a warm day, the bearing and seal have usually been deteriorating for months. Replacing the pump at the first sign of weep or noise is far cheaper than dealing with a warped head afterwards.
Browse the Yuchai pump category, and pair the pump with the YC4108 water pump D0305-1307020B or the YC4108 oil pump D30-1011100.



Compare the pulley and inlet arrangement, or send us a photo of the old pump.
Yes, the gasket is supplied.
Only to reach a workshop.
The pump comes with the hub.
EPID supplies diesel engine parts for Weichai, Baudouin, Yuchai, Caterpillar, Sinotruk, FAW Xichai and Cummins engines. Every order is checked against the original part number before packing. Ask for a quotation with your model and quantity and we will reply within one working day.